Vertical Roof or Inline-Mount
Single or Two Stage; Axial or Axcentrix; Direct or Belt Drive
Heavy Gauge Steel and Continuous Welding
Application: Food Processing, Glass, Breweries, Chemical Plants, Pulp, Paper, Meat Packing, Hot Metal, Rubber, Dairy
|
|
Wall-Mount Propeller Fans
Direct or Belt Drive
Applications: General Supply and Exhaust for Warehouses, Factories, and Mechanical Rooms
Capacity: Up to 68,172 cfm; 0 - 1.8” w.g.
|
|
Square Inline Duct-Mount
Direct or Belt Drive
Application: Supply, Return, or Exhaust Air for General HVAC Systems
Capacity: From 103 - 27,502 cfm; 0 - 3.5” w.g.
Inlet Filter Box with 1" or 2" Filters
|
|
Roof-Mount, Spun Aluminum Downblast
Direct or Belt Drive
Application: General Exhaust for Schools, Churches, and Office Buildings
- Capacity: From 44 - 46,640 cfm; 0 - 1.5" w.g.
Miami-Dade Approved for High Velocity Hurricane Zones (NOA# 10-0615.09)
|
| Roof-Mount, Low Contour Propeller Downblast Application: General Exhaust or Supply for Low Pressure Systems Capacity: Up to 2460 cfm; 0 - 1.25” w.g.
|
|
Class I Heavy-Gauge Galvanized Steel, Roof/Floor/Inline Mount Utility Blower
Belt Drive; Backward Inclined Wheel
Application: Commercial Kitchen and Fume Exhaust, Building Pressurization and Fresh Air Supply
U.L. 762 Rated for Grease Laden Air Exhaust (500°F)
UL Rated for Smoke Control Systems (500°F / 4-Hours; 1000°F / 41-Minutes)
Capacity: From 500 - 29,150 cfm; 0 - 5.0” w.g.
|
|
Stand-alone Energy Recovery Units
Application: Recover Exhaust Air Energy and Reintroduce it into Conditioned Space
5 Configurations: D-Series - Rooftop Downward Discharge Duct Arrangement; S-Series - Rooftop Side-by-Side Duct Arrangement; O-Series - Rooftop Over-and-Under Duct Arrangement; M-Series - Mechanical Room Side-by-Side Duct Arrangement; N-Series - Mechanical Room Over-and-Under Duct Arrangement
Capacity: Up to 6,200 cfm, 0 - 1.5” w.g.
ARI Certified Energy Recovery Wheel
|
| Class I, II Heavy-Gauge Steel, Mixed Flow Inline Fan Belt Drive Patented Wheel Design Application: Exhaust, Supply, or Return Air in Ducted (Medium to High) Pressure Systems Requiring Lower Sound Levels Capacity: From 1,300 - 155,000 cfm; 0 - 7.0” w.g. U.L. 762 Rated for Smoke Control Systems (500°F / 4-Hours; 1000°F / 1-Hour) U.L. 762 Rated for Grease Laden Air Exhaust (400°F & 500°F)
|
| Roof-Mount, Spun Aluminum Upblast -
Direct or Belt Drive Application: Fumes, Commercial Kitchens, and Exhaust of Other Contaminants U.L. Rated for Smoke Control Systems (500°F / 4-Hours; 1000°F / 1-Hour) U.L. 762 Rated for Grease Laden Air Exhaust (400°F) Capacity: From 54 - 30,609 cfm; 0 - 4.7” w.g. MIami-Dade Approved for High Velocity Hurricane Zones (NOA#10-0615.09)
|
| Roof-Mount Upblast Belt Drive Application: Laboratories, Hospitals, Research Centers, and Institutions Capacity: From 350 - 80,000 cfm; 0 - 18.0” w.g.
|
| Hooded Roof Gravity Ventilators Galvanized or Aluminum Construction Application: Building Pressure Relief and Fresh Air Intake Capacity Range: Up to 72,000 cfm
|
| Turbines: General Ventilation of Factories, Farm/Agricultural Buildings, Commercial/Public Structures, and Homes Pul-Air for Air Exhaust with No Moving Parts Insul-Air for Extended Airshaft to Clear Roof Peaks, etc.
|
| Capacity: 75 - 1,200 MBH; 600 - 14,800 CFM Horizontal Arrangement for Indoor & Outdoor Gravity & Power Venting Aluminized Steel Heat Exchanger & Burner
|
| GBD – Vented Base GBC – Dual Motor GBH – Less Base Belt Drive Application: Exhaust of grease-laden air from commercial kitchens Capacity Range: 500 – 14,000 cfm; 0–5” w.g.
|
| Roof-Mount Propeller Upblast Direct or Belt Drive Standard Height or Low Profile Application: Rapid Air Removal or General Ventilation Exhaust U.L. 793 Heat & Smoke Option (500°F / 4-Hours; 1000°F / 15-Minutes)[HS Model] Capacity: Up to 82,481 cfm; 0 - 1.0” w.g.
|
| Heavy-Duty Construction, Hooded Roof-Mount Propeller Fans Direct or Belt Drive Application: Supply Fresh Air or Exhaust Hot, Humid, and/or Foul Air Capacity: Up to 72,755 cfm; 0 - 0.5” w.g.
|
| Roof-Mount Upblast Plenum Mounting of Multiple Fans; Redundant Fan System Belt or Direct Drive Application: High Velocity Fume Exhaust of Laboratories, Hospitals, Research Centers, and Institutions Capacity: From 2,850 - 54,960 cfm; 0 - 8.5” w.g.
|
| Heavy-Duty, High Pressure Construction, Free Standing SWSI Industrial Fan Belt Drive 3 Wheel Types: General, Fibrous Material Handling, and Air Handling Application: Ventilation or Exhaust of Dust, Granular Materials, and Fibrous Materials as well as Air Handling Capacity: UP to 60,000 cfm; 0-30" w.g.
|
| Kitchen Hood | PBKH
Exhaust Canopy, Self-compensating, Low Profile Exhaust, and Vapor Hoods
UL/ETL/NSF Listed and Built in Accordance with NFPA 96
304 or 430 Stainliess Steel, Fully Welded construction
Wall or Island Mounting Options
Application: Exhaust of Grease, heat, Steam and Vapors from Commercial Kitchens
Capacity: Built to Meet Jobs Specifications
|
| Roof-Mount, Low Contour Downblast Direct or Belt Drive Application: General Exhaust for Schools, Churches, and Office Buildings Capacity: From 39 - 17,516 cfm; 0 - 1.5” w.g.
|
| Roof-Mount, Low Profile, Louvered Exhaust Fan Architectural, tiered Hood Design Direct or Belt Drive Application: General Exhaust for Schools, Churches, and Office Buildings - Capacity: From 44 - 46,640 cfm; 0 - 1.5" w.g.
|
| Roof-Mount Filtered Supply Direct or Belt Drive Side Intake [FS Model] Application: Supply Fresh Air to Buildings or Systems by Replacing the Exhaust of Contaminated Air [ie: Commercial Kitchens] Capacity: From 100 - 14,426 cfm; 0 - 1.0” w.g.
|
| Ceiling-Mount or Interior/Exterior Wall-Mount Fan Heavy-Gauge Steel Belt Drive Application: General Exhaust or Supply Requiring Unique Mounting of Fan Capacity: From 400 - 30,400 cfm; 0 - 7.0” w.g.
|
| Roof-Mount Architectural Tiered Hood Design Gravity Air Intake or Relief Applications: Building Pressure Relief and Fresh Air Intake Compatible with Linea Centrifugal Exhausters
|
| Class I, II, III Heavy-Gauge Steel Construction, Unhoused Centrifugal Belt Drive High Efficiency Airfoil and Backward Inclined Wheels (Plenum is Airfoil Only) Application: Supply Air in a Pressurized Plenum for Built-up Air Handling System; excellent for Retrofit or Replacement Systems
Capacity: Up to 264,000 cfm; 0-10.0" w.g.
|
| Hooded, Roof-Mount Propeller Fans Direct or Belt Drive Application: Supply Fresh Air or Exhaust Hot, Humid, and/or Foul Air Capacity: Up to 72,755 cfm; 0 - 0.5” w.g.
|
| Tubular Inline Duct-Mount Aluminum Construction Direct or Belt Drive Application: Supply or Return Air; Exhaust Fumes or Humid Air Capacity: From 75 - 22,054 cfm; 0 - 3.0” w.g.
|
| Make Up Air | SDF
- Direct-Fired or indirect-Fired Gas Heating and Ventilation
- ETL Listed and CSA Certified to ANSI Design Standards
- Application: Supply Tempered Fresh Air to Buildings or commercial Kitchens by Replacing the Exhaust of Contaminated Air
- Capacities: direct-Fired - Up to 1,500 MBH and 14,000 CFM, indirect-Fired - Up to 1,200 MBH and 14,8000 CFM
|
| Class I, II, III Heavy-Gauge Steel Construction, Tubular Centrifugal Inline Fan Belt Drive Backward Inclined and Airfoil Wheels Horizontal or Vertical Mount Application: Exhaust, Supply, or Return Air in Ducted (Medium to High) Pressure Systems Capacity: From 49 - 46,640 cfm; 0 - 10” w.g.
|
| Low to Medium Pressure Ducted Applications Direct or Belt Drive Horizontal or Vertical Mount Application: Exhaust Contaminated/Hot Air and Supply Air to Cool/Pressurized Interior Spaces Capacity: Up to 150,000 cfm; 0 - 2.5” w.g.
|
| Heavy-Duty Construction, Roof-Mount Propeller Upblast Direct or Belt Drive Standard Height or Low Profile Application: Rapid Air Removal, High Temperature, or General Ventilation Exhaust Capacity: Up to 82,481 cfm; 0 - 1.0” w.g.
|
| Roof Mounted Utility Blower UVF (Standard Configuration) UVF_CM (Roof Curb Mounted) Class I Heavy-gauge Galvanized Steel Backward Inclined Wheel
|
| High Pressure Ducted Applications Direct or Belt Drive Horizontal or Vertical Mount Application: Exhaust Contaminated/Hot Air and Supply Air to Cool/Pressurized Interior Spaces Capacity: Up to 120,000 cfm; 0 - 7.0” w.g.
U.L. 762 Rated for Smoke Control Systems (500°F / 4-Hours; 1000°F / 15-Minutes - VXD Only)
|
| Class I, II, III, IV Construction, Free Standing SWSI/DWDI Centrifugal Fan Belt Drive Backward Inclined and Airfoil Wheels Application: Exhaust and Supply in Typical Duct Systems; Able to Handle Many Special Environments such as High Temperature, Corrosive, and Spark Resistant Capacity: Up to 264,000 cfm; 0 - 10.0” w.g. Listing UL762 rated for Grease Laden Air
|
| Heavy-Duty Construction, Wall-Mount Propeller Fans Direct or Belt Drive Applications: Supply/Exhaust for Warehouses, Factories, and Mechanical Rooms Capacity: Up to 323,000 cfm; 0 - 1.8” w.g. Capacity: Up to 264,000 cfm; 0 - 10.0” w.g.
|
| Low Silhouette, Spun Aluminum Design Applications: Pressure Relief, Discharge Cap, Outside Air Inlet Hood Capacity: Up to 20,065 cfm
|
| Ceiling or Inline Mount Low Sound Levels Direct Drive Application: General Exhaust for Lavatories, Conference Rooms, and Institutions Capacity: From 32 - 3,290 cfm; 0 - 1.5” w.g.
U.L. Rated for Use Over bath Tubs and SHowers When Connected to a GFCI Protected Branch circuit |
| Inline Duct-Mount Belt Drive Application: General Purpose Duct Blower for Heating/Cooling Systems ZC (Single) Capacity: From 750 - 6,350 cfm; 0 - 1.5” w.g. ZCC (Twin) Capacity: From 1,500 - 12,700 cfm; 0 - 1.5” w.g.
|
|